İletişim Bilgileri

WET ALARM VALVE

WHAT IS A WET ALARM VALVE?

WET ALARM VALVE; If we answer the question of what is a Wet Alarm Valve; Designed for applications where water is not likely to freeze. Pressurized water in the pipes is discharged to the fire area as a result of the sprinkler being activated due to the fire. While the pressurized water system is fed continuously, it also fills the delay cell at the same time. After filling the cell, the pressure switch on the cell is triggered. The pressure switch transmits alarm information to the fire alarm system or automation system. After the pressure switch is triggered, the water reaches the water motor gong and provides a mechanical alarm. This system is designed for heated volumes and needs where the water does not fall below +4 °C and does not freeze. Alarm check valve or water flow detector are used to give mechanical and electronic alarms.

WHAT IS A WET ALARM VALVE AND WHAT ARE THE GENERAL FEATURES?

Wet alarm valve is used in wet type fire extinguishing systems. It is used for applications where the water is above freezing temperature, ensuring that the pressurized water in the pipes is delivered to the fire area as a result of the sprinkler being activated in the event of a fire.

  • The water, which is pressurized in the pipes, is discharged to the fire area as a result of the sprinkler activation.
  • Pressurized water fills the delay cell at the same time as the system is fed continuously.
  • After the cell is full, the pressure switch on the cell is triggered.
  • The pressure switch transmits alarm information to the automation system.
  • Water reaches the motor gong and provides a mechanical alarm.

KEY FEATURES

Especially in wet type sprinkler systems, automatic sprinkler is fixed to pipe systems that are connected to a water source and contain water. In these systems, the sprinkler opens with the effect of the heat generated by the fire, and they allow the water to start pouring onto the burning materials. The effect of the heat from the fire activates any sprinkler connected to the system and ensures the flow of water. The released water is scattered by hitting the reflector in the sprinkler and is discharged into the fire area in the form of a smooth sprinkler. Depending on the conditions in the area of use, sprinklers are designed to activate at a specified temperature between 40°C and 350°C. Most sprinklers discharge approximately 70 to 100 liters of water per minute into the fire scene.

The wet sprinkler system can be divided into zones fed from a common column. The system zone size is determined depending on the fire hazard class of the building. In high storage areas, the maximum floor area on each floor connected to any feed column should not exceed 3716 m². If a sprinkler zone addresses multiple floors or separate occupancy zones, a traceable shut-off valve, flow switch, and test and drain valve should be installed at the entrance to the floors or zones. In the wet pipe sprinkler system, the pipes are kept constantly filled with pressurized water. It is applied only in places where there is no risk of freezing and the ambient temperature does not exceed 95 °C.

Experiences are taken into account regarding people’s safer lives in their living spaces. In this way, different standards and processes are created. The fire code standards applied in this way also include a certain system. In this system, the wet alarm valve takes on the biggest task. Due to its working principles, it ensures that the sprinkler system, which is the first responder to the fire, works effectively and smoothly. These valves, which act like a kind of heart, are responsible for activating the entire extinguishing system. Similarly, there is a dry alarm valve in check valves. However, their working principles are different. Valves used for wet areas should always have the principle of working smoothly and appropriately within the system. Wet alarm valves are used in areas where the water is not likely to freeze. It gives both mechanical (with engine gong) and electrical (pressure switches) alarms with the direction of the trim set due to the pressure difference created by the activation of the sprinklers during the fire. Can be used with delay cell to prevent false alarms.

PRODUCT INFORMATION

Wet Alarm Valve is a check valve used in wet pipe sprinkler systems to activate electrical and mechanical alarms with water flow from one or more opened sprinklers. Wet alarm valve operating principle As long as the water pressure in the sprinkler installation is equal to or more than the supply water pressure, the alarm valve is in the closed position. By opening one or more sprinklers, the wet alarm valve flap opens and water starts flowing into the system and delay chamber. When the delay chamber is completely filled with water, the pressure switch and the water alarm gong are activated by the water pressure. After the fire is brought under control, the water flow to the area can be stopped by closing the shut-off valve in the wet alarm valve station of the area where the sprinkler is opened.

In particular, one wet alarm valve should be used in each wet pipe sprinkler zone. A shut-off valve should be placed below each alarm valve. Moreover, if the sprinkler alarm valves are fed from the ring main supply line arranged inside the building, the main supply ring should be divided into zones with regional control valves. In addition, it is allowed to feed to a maximum of 4 alarm valves from each part of the ring. The diameter of the alarm valve should be selected according to the diameter of the fire zone installation column, which is determined by hydraulic calculation.

These valves, which can control both electricity and mechanics, are of vital importance in fires. In particular, the wet alarm valve in the check valves group has an important place in the sprinkler system. It is also important to adjust the water pressure as needed. The valve remains closed when the pressure is equal or greater. If one or more sprinklers are opened, the clamp of the wet alarm valve is also opened and water flow to the required cells begins. At this time, the water alarm gongs are activated by the prosostat with the water pressure created. In other words, alarm valves start to work functionally. When the fire goes out or the situation in question disappears, the shut-off valve is closed from the station and the water going to the area is stopped. This system is very useful and will allow quick intervention until the teams arrive.

What is Wet Alarm Valve and Its Uses

  • Warehouses
  • Workshops
  • Hospitals
  • Living Centers
  • High-Rise Residences and Residences
  • Factories
  • Homes
  • Hospitals
  • Schools and universities
  • Hotel and dormitory buildings
  • Shopping malls
  • Cafeteria and restaurants

About Go Valve

As the GoValf team, we have been bringing together mechanical installation supply solutions in accordance with current technologies in Turkey and neighboring countries since 2009 with our customers. While we offer the most exclusive brands of Turkey and the world to our customers at the most affordable prices, we are adding new ones to our solutions every day.

Today, we categorize our departments in the following subjects, and with our expert teams and nearly 100 brands, we offer our customers privileged services from basic to delivery in their projects;

  1. Plumbing Equipment,
  2. Fire Extinguishing Systems and Equipment,
  3. Pumps and Boosters,
  4. Heating Solutions,
  5. Air Conditioning and Ventilation

Moreover, in our sector where competition is increasing day by day, we have increased our quality and diversity with various products that we manufacture by following the technologies. In addition, we design, cast, manufacture, assemble, test and control the products we produce in our own facilities with our own expert team. Our priority is the peace and happiness of our customers. We serve our customers with the assurance of GoValf. With our understanding of safe, high quality, stable work and competitive prices, we are working with all our strength to be in cooperation not only for today but forever. The trust of our customers in us is our biggest capital. We continue to offer you the most affordable prices and the highest quality services by achieving a healthy cooperation with our suppliers, based on data and information, in harmony with customer requests with engineering solutions. In particular, we carry out the design, casting, production, assembly, testing and check-ups of the products we produce in our own facilities with our own experienced staff. In our sector, where the competition is increasing day by day, we have increased our quality and diversity with various products that we manufacture by following the technologies.